FinelineApplications
Resolutions of 10, 7, 5 or 2 µm
ApplicationPhotoheadResolutionMachine Platform
QTA, MLB, HDI, CMLLS3030 µm L/SMDI-ST (XL)
MDI-TTG
MDI-Flex (XL)
Advanced HDI, mSAP, FPC, CMLLS1515 µm L/SMDI-ST (XL)
MDI-TTG
MDI-FLEX (XL)
MDI-ST ULTRA
mSAP, FPC, ICS, CMLLS1010 µm L/SMDI-ST ULTRA
MDI-TTG ULTRA
mSAP, PKG, ICS, PLPLLS077 µm L/SMDI-ST ULTRA
MDI-TTG ULTRA
PKG, ICS, PLP, WLP, FOWLPLLS044 µm L/SMDI-ST ULTRA
PKG, ICS, PFP, WLP, FOWLPLLS25002.5 µm L/SMDI-ST ULTRA

 

QTA = Quick Turn Around | MLB = Multilayer Boards | HDI = High Density Interconnect | CM = Chemical Milling | mSAP = Modified semi-additive processes | FPC = Flexible PCB
ICS = IC Substrates | PKG = Packaging | PLP = Panel level packaging | WLP = Wafer level packaging | FOWLP = Fan out wafer level packaging

Finelineimaging
Highest accuracy and resolution

MDI-ULTRA - Highest accuracy and precision platform for substrate, packaging and related applications. The ultra-precision machine design applies specific materials for critical components at selected positions in the machine to enable reaching greater accuracy and precision as well as maintaining the overall system with high stability. Adding the high resolution imaging system, combined with its real-time autofocus function makes this the suitable platform for advanced electronics or high-tech packaging applications.

Whether as R&D-tool or production equipment, manual or fully automated handling, the Schmoll MDI Team is happy to learn about your requirements and present a suitable solution.  

Fineline imagingHigh-precision platforms

Max. panel size
No. of heads
Overall dimensions
MDI-ST ULTRA
622 mm x 610 mm (*)
1 - 6
2660 mm x 1400 mm
TECHNICAL DATA
MDI-TTG ULTRA
700 mm x 700 mm
1 - 7
2900 mm x 2140 mm
TECHNICAL DATA

*depends on machine configuration

MDI-ST ULTRA
Single table machine
MDI-TTG ULTRA
Tandem table machine
HighlightsOptions

A selection of product highlights and configuration options.

Granite vacuum table

High resolution systems come with the challenge of a reduced optical depth of focus (DoF). The flat table surface of the sophisitcated manufacured granite vacuum table ensures a flat stage across the entire table area to ensure best in focus imaging at highest resolution. The real-time autofocus function adds to the compensation capability that allows the system to generate a stable imaging result of finest lines and features with high uniformity.

Handling options

Handling options in the area of high resolution imaging applications can vary from small to large panel substrates to round wafers. Different materials (type and shapes) require different handling.

Benchmarks

Contact us to schedule a first meeting or call to understand your specific requirements. Schmoll is equipped to support benchmark tests and backed by a vast network to material suppliers and industry experts.

ContactForm

Contact

Select Language