X-Ray Systems | XRC | XRI |
# of stations | 1 / 1 | 1 / 1 DH |
Max
Panelsize XY (from prism) |
654x650 mm 25.7"x25.6" |
654x650 mm 25.7"x25.6" |
Base | Granite | Granite |
XY - Motor / Vmax | Linear Motor 90 m/min |
Linear Motor 100 m/min |
Z - Motor / Vmax | Linear Motor 25 m/min |
Linear Motor 25 m/min |
#
of max tools tool boxes |
1 x 110 bis 1 x 660 | 1 x 110 |
Vakuum table | Yes | Yes |
Standard toolind system | Yes | No |
Spindle | T160, T200, SM250S, D1331-26/36 |
T160, T200, SM250S, D1331-26/36 |
Accuracy | +/- 18 µm | +/- 18 µm |
Cpk Value (Schmoll System) | >1.67 | >1.67 |
Applications | ||
Multi layer drilling | +++ | +++ |
Routing | +++ | — |
+++ = excellent ++ = pretty good + = good — = not recommended | ||
X - Ray application | ||
X-Ray Source | 70 KV / 180 µA | 70 KV / 180 µA |
Counter part | ![]() |
![]() |
Max # of layers | 99 | 99 |
Multizone detection | ![]() |
![]() |
Options | ||
Clamping system | ![]() |
— |
Loader | ![]() |
![]() |
Contact Depth Drilling | ![]() |
— |
OAC Offset Kompensation | ![]() |
— |
2nd measurement system | ![]() |
— |
CCD | ![]() |
— |
Installation | ||
Weight | 5900 kg | 5900 kg |
Max floor loading * | 2000 kg/m² | 2000 kg/m² |
Dimensions LxBxH | 2250x1670x1900 mm | 4050x1920x1778 mm |
Electric specification | 380/400 V; ±5% 50/60 Hz 3 Phase; 23 KVA |
380/400 V; ±5% 50/60 Hz 3 Phase; 23 KVA |
Pneumatic specification | 7 - 7.5 bar | 7 - 7.5 bar |
* no further requirements |